Compact AC Power Supply TOS9300 Series 4 Models
The TOS9300 Series high performance electronic load is the successor to the highly respected PLZ-4W series, whilst still retaining the same high specification and build quality. Advances include a high visibility color display, low voltage operation from a minimum of 1 V to a maximum of 150 V. Programmable profiles of voltage/current can be applied (using the new ARB function, as used in LED/solar testing) in addition to the inherited 6 modes of operation: Constant Current, Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Resistance + Constant Voltage.
TOS9300 | Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V),Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
---|---|
TOS9301 | Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Max output-voltage of DC hipot testing: 5kV /20mA,7.2kV / 13.9mA(100W), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V / DC+50V to +7200V), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9301PD | Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Max output-voltage of DC hipot testing: 5kV /20mA,7.2kV / 13.9mA(100W), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V / DC+50V to +7200V), Max Output-voltage of Partial discharge 5.000 kV / Measurement range of Partial discharge 0 to 10000 pC, Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9302 | Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Measurement range of ground bond testing: 0.001M Ω to 0.600G Ω (3.0A to 42.0A), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9303 | Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Max output-voltage of DC hipot testing: 5kV /20mA,7.2kV/13.9mA(100W), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V / DC+50V to +7200V),Measurement range of ground bond testing:0.001 Ω to 0.600 Ω(3.0A to 42.0A), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9303LC | Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Max output-voltage of DC hipot testing: 5kV /20mA,7.2kV/13.9mA(100W), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V / DC+50V to +7200V), Measurement range of ground bond testing: 0.001 Ω to 0.600 Ω(3.0A to 42.0A), Measurement range of leakage current testing: 1μA to 100mA(rms), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |