The PLZ-5W Series high performance electronic load is the successor to the highly respected PLZ-4W series, whilst still retaining the same high specification and build quality. Advances include a high visibility color display, low voltage operation from a minimum of 1 V to a maximum of 150 V. Programmable profiles of voltage/current can be applied (using the new ARB function, as used in LED/solar testing) in addition to the inherited 6 modes of operation: Constant Current, Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Resistance + Constant Voltage.
PLZ205W | DC Electronic Load: Max. 200 W, 1–150 V, 40 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. |
---|---|
PLZ405W | DC Electronic Load: Max. 400 W, 1–150 V, 80 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. |
PLZ1205W | DC Electronic Load: Max. 1200 W, 1–150 V, 240 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. |
PLZ2405WB | Booster unit for PLZ1205W: Max. 2400 W, 1–150 V, 480 A. Able to connect up to four PLZ2405WB units in parallel to each PLZ1205W master unit (max. 10.8 kW, 2160 A). (Dedicated booster for PLZ1205W. Unable to connect to other models.) |
PLZ6005W SR | Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 6000 W, 1–150 V, 1200 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.” |
PLZ15005W SR | Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 15.6 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.” |
PLZ20005W SR | Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 20.4 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.” |
PLZ205WZ (SPEC21192) | DC load device with impedance measurement function in PLZ - 5W series. DC Electronic Load: Max. 200 W, 1–150 V, 40 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements. Measures AC frequency from 100 Hz - 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. Zero adjustment function allows for increased accuracy during critical impedance measurements. |
PLZ405WZ (SPEC21192) | DC load device with impedance measurement function in PLZ - 5W series. DC Electronic Load: Max. 400 W, 1–150 V, 80 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements. Measures AC frequency from 100 Hz - 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. |
PLZ1205WZ (SPEC21192) | DC load device with impedance measurement function in PLZ - 5W series. DC Electronic Load: Max. 1200 W, 1–150 V, 240 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements.Measures AC frequency from 100 Hz - 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. |