Background Image
MU909014A1/B/B1/C/C6

MU909014A1/B/B1/C/C6

OTDR

Introducing the handheld OTDR that does not compromise performance – the µOTDR MU909014A1 from Anritsu. With performance that rivals traditional OTDRs that are four times the size and more than double the price, the Network Master MT9090A has created a class of test instruments. It features 5 cm resolution for accurate mapping of events, deadzones of less than 1 meter (3-feet) and a dynamic range of up to 32.5 dB – enough to test over 150 km (90 miles) or PON-based FTTx networks featuring up to a 1 x 64 split. The MT9090A also takes portability to a new level by being the first handheld OTDR that truly fits in the palm of your hand.

  • - High-end OTDR performance in a pocket-size package
  • - Exclusive, integrated launch fiber provides accurate initial connector measurement without external devices
  • - Excellent mid-range performance where it matters most
  • - "Fiber Visualizer" mode simplifies operation, no OTDR knowledge needed
  • - Bluetooth, Wi-Fi and Ethernet connectivity
  • - Complete PON testing through splitters up to 1 x 64
  • - High resolution and extremely short deadzones ensure thorough short fiber evaluation
  • - Rugged, sealed design provides years of service in the most challenging environments
  • - High resolution, widescreen color display that is easy to read indoors or out
  • - Modular platform ensures maximum return on investment
  • - Compact and lightweight design for maximum portability in the field
  • - Complete fiber maintenance tool including optical power meter and visible source "red light"
  • - 1625 nm & 1650 nm models for in-service maintenance and troubleshooting
  • - High performance without a high price
  • Center Wavelength : 1310/1550 ±20 nm - 1625 ±15 nm, 1310/1550 -
  • ±20nm, 1650 ±15 nm 1310/1490/1550 ±20 nm, 1310/1550 ±20 nm - 1625 ±15 nm, 1310/1550 ±20 nm - 1650 ±15 nm.
  • Dynamic Range : 38 dB/37 dB/35 dB, 10 38 dB/37 dB/35 dB, 10 36 dB/35 dB/35 dB 32.5 dB/31 dB/32.5 dB, 11 32.5 dB/31 dB/32.5 dB.
  • Dead Zone : Fresnel ≤0.8 m (Typical), Backscatter ≤4.0 m (1310 nm, Typical), ≤4.5 m (1490/1550/1625/1650 nm, Typical).
  • Number of Sampling Points : <250,001 pts (Course: <7,501 pts, Medium: <20,001 pts, Fine: <250,001 pts).
  • Sampling Resolution : 2 cm (min.)
  • Testing Modes : OTDR (Full automatic, Manual, Real time), Power Meter, [Video Inspection Probe (Option)]. [PON Power Meter, Loss Test Set, Light Source (MU909015C6, MU909014C6)].
  • Environment : Operating temperature and humidity: –10°C to +50°C, <95% (no condensation). Storage temperature and humidity: –30°C to +70°C, <95% (no condensation). Vibration: MIL-T-28800E Class 3, Ingress Protection Rating: IEC60529 IP51.
Have any Questions?