The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 240V. Conducted noise can be measured on the phase and on the neutral conductor. The TBLC08 is equipped with a switchable limiter/attenuator and an artificial hand connection.
The device is available with country-specific DUT connectors
▪ Frequency range: 9 kHz to 30 MHz
▪ Impedance: 50 Ω ║ (50 µH + 5 Ω)
▪ Artificial hand: 220 pF + 511 Ω
▪ Switchable PE: 50 Ω ║ 50 µH
▪ Limiter / attenuator: 150 kHz to 30 MHz; 10 dB
▪ Air core inductors
▪ Line voltage: max. 240V / 50 – 60 Hz, CAT ‖
▪ Max. current: 8A @ 23°C
▪ DUT socket: country specific
▪ Measurement connector: 50 Ω BNC
▪ Power connector: IEC 60320 C13
▪ Operating Temperature Range: +5°C … + 40°C; 5% to 80% RH
▪ Safety: Safety Class I, IEC 1010-01