- Equipment to be tested is single-phase/three-phase equipment (40 A/phase).
- Supports IEC 61000-3-2 Ed 5.0 (2018) for harmonics standards and IEC 61000-3-3 Ed 3.1 (2017) for flicker standards.
- The screen can be easily switched between Japanese and English display.
- With/without/with (2nd and higher orders) inter-order harmonic measurement Compatible with all measurement technology standards.
- No need for a PC for compliance testing.
- Real-time measurement that gives you a quick grasp of the EUT status.
- Assist function that guides you on standards and tech-nical terms.
- Test reports available in both PDF and text formats.
Harmonic/Flicker Analyzer (Three-phase/single-phase, high-current-capable type)
The KHA3000 is a model that, in addition to the compatible standards and functions of the popular KHA1000, is equipped with the IEC 61000-3-12 (harmonics) and IEC 61000-3-11 (flicker and voltage fluctuation) standards required for harmonic and flicker standard tests of single- and three-phase equipment exceeding 16 A. This model enables high-precision, simultaneous three-phase measurements of up to 40 A/phase using only this unit. In addition to a real-time display that can be used like an *1 oscilloscope or FFT analyser, it is of course also equipped with a real-time standard judgement function. This model alone can perform everything from standards determination to test report creation without the need for a PC.
Features
Key capabilities and advantages
Specification
Technical specifications and parameters
| KHA3000 | KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase. |