- For IEC 61000-4-6 Testing
- RF Power Amplifiers
- Wide Selection of CDNs
- Software Automation
- Directional Couplers
- Attenuators
Conducted Immunity Test - 25 Watts
CIS-25 Conducted Immunity System is a 25-watt conducted immunity test system designed to meet IEC 61000-4-6 requirements. It includes an ACS series power amplifier, Coupling Decoupling Network (CDN), directional couplers, attenuators, cables, and optional CSAT software. When properly configured, the system supports conducted immunity testing up to 230 MHz at all IEC-specified test levels. A wide range of Com-Power CDNs is available for customization to suit specific applications. With compatible signal generators and spectrum analyzers, CSAT software enables fully automated calibration and testing. All Com-Power CDNs are calibrated to the latest CISPR 16 standards.
Features
Key capabilities and advantages
Specification
Technical specifications and parameters
| Power Amplifier | ACS-230-25W |
| CDNs | To be determined at the time of purchase |
| Attenuator | ATTN-6-100W |
| Attenuator | ATTN-30-100W |
| Directional Coupler Unit | DCU-1000-100W |
| Cable Set | Included |
| CDN Shorting Adapters | Appropriate adapters included |
| Impedance Adapters | ADA-515 (150 Ohm to 50 Ohm) |
| Terminator | 50 Ohm |