- Frequency range 150 kHz to 230 MHz
- Designed for IEC / EN 61000-4-6
- 75 Ohm coaxial cables
- Individual calibration included
- Three-year warranty
- Female BNC RF disturbance signal coupling port
- Handles up to 40V RF input voltage
- Unpainted bottom surface for effective grounding
- Fully complies with CISPR 16-1-2
- Part of CIS series conducted immunity test system
150 kHz to 230 MHz
The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF Input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding. Com-Power CDN-C75E is a part of the series of Coupling/Decoupling Networks designed for testing product for conducted immunity per IEC/EN 61000-4-6. The Com-Power CDN-C75E fully complies with the requirements contained in the CISPR 16-1-2. All Com-Power CDNs are individually calibrated and can be purchased separately or as part of the CIS series conducted immunity test system. This is a pre-packaged solution for the EMC testing that includes all required accessories and ACS series power amplifier.
Features
Key capabilities and advantages
Specification
Technical specifications and parameters
| Product Name | Coupling Decoupling Network (CDN) |
| Compliant Test Standards | IEC / EN 61000-4-6 |
| Application | 75 Ohm Coaxial Cables |
| Frequency Range | 150 kHz to 230 MHz |
| RF Input Voltage | 40 V (Max) |
| RF Input Connector | 50 Ω BNC (Female) |
| Voltage Rating | 310 V AC / 440 V DC (Line to Ground) |
| Current Rating | 1 Amp (Max) |
| AE and EUT Connections | 4 mm shrouded banana sockets |
| Common Mode Impedance | 150 kHz - 26 MHz: 150Ω ± 20Ω, 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω, 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω |
| Voltage Division Factor | 9.5 dB +3 / -1 |
| Decoupling of Common Mode Disturbance | ≥ 40dB (EUT/AE) |
| Dimensions | 6 x 6 x 13 inches or 15.2 x 15.2 x 33 cm |
| Weight | 5 lbs or 2.3 kg |